Loading…

Variable Name: response_code

Variable ID: 0x0096

Variable Label: Response code

Variable Help: Command Specific Response Code- Data that is returned in the Field Device response, that indicates the relative success of the Command sent in the Host request. This information may relate to the Data of the Host request or to the command itself.

Variable Handling: R

Variable Class: Diagnostic | HART

Variable Size: 1

Variable DataType: Enum

Variable Enum Value Variable Enum Text
0x0000 Success
0x0002 Invalid selection
0x0003 Value was too high
0x0004 Value was too low
0x0005 Too few data bytes received
0x0006 Field device specific error
0x0007 In write protect mode
0x0010 Access restricted
0x0020 Busy
0x0021 Delayed response initiated
0x0022 Delayed response running
0x0023 Delayed response dead
0x0024 Delayed response conflict
0x0040 Command not implemented

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
161 4040 read_cidra_control
163 4048 read_cidra_device_info
165 4059 read_cidra_pipe_info
167 4064 read_cidra_fluid_prop
169 4073 read_cidra_environment
171 4083 read_cidra_display
173 408D read_cidra_system
175 4090 read_cidra_system_dynamic
177 4099 read_cidra_preamp
179 40B2 read_cidra_flow_algorithm
181 40B7 read_cidra_flow_algo_dynamic
183 40BC read_cidra_flow_cal
185 40D3 read_cidra_sos_algorithm
187 40D6 read_cidra_sos_algo_dynamic
191 40E2 read_cidra_analog_section
193 40E9 read_cidra_input_units
195 40ED read_cidra_flow_nr_filter
197 40F1 read_cidra_flow_damping_filter
199 40FA read_cidra_flow_spike_filter
201 40FE read_cidra_gvf_nr_filter
203 4102 read_cidra_gvf_damping_filter
205 410B read_cidra_gvf_spike_filter
207 4110 read_cidra_sensor
209 411A read_cidra_sensor_spacing
213 4129 read_cidra_measured_values
215 413A read_cidra_sensor_max_min
217 4143 read_cidra_sensor_alpha
0 00AE read_unique_identifier
1 00AF read_pv
2 00B0 read_pv_current_and_percent_range
3 00B1 read_dynamic_variables_and_pv_current
9 00DD read_device_variables_and_status
7 00DB read_loop_configuration
8 00DC read_dynamic_variable_classification
14 00B6 read_pv_sensor_info
15 00B7 read_pv_output_info
12 00B4 read_message
13 00B5 read_tag_descriptor_date
16 00B8 read_final_assembly_number
20 00DE read_long_tag
48 1043 read_additional_device_status
48 1043 read_additional_device_status
33 1054 read_device_variables

Variable Write Command List

None