Variable Name: var_ds_fCurrentLowerLimit
Variable ID: 0x4044
Variable Label: Current Lower Limit
Variable Help: Current Lower Limit Lower limit of the current range for the 4-20 mA current output. For adjustment purposes or to safely identify an over or under measuring range condition, the current range available for the measurement signal is extended beyond the standard range of 4 mA and 20mA. According to the Namur specifications (NE 43), the lower current value must not be less than 3.8 mA. The limits can be set within the range from 3.8 mA to 4 mA.
Variable Handling: R/W
Variable Class: AnalogOut
Variable Size: 4
Variable DataType: Float
Variable Display Format: |en|.2f
Variable Edit Format: |en|.2f
Variable Unit:
Variable Max:
Variable Min: