Variable Name: device_specific_status_1

Variable ID: 0x102C

Variable Label: Status Group 1

Variable Help: Field Device Specific Status Byte 2- Data that has Field Device status information relating to: failures / warnings / status of process's.

Variable Handling: R

Variable Class: Dynamic | Diagnostic | Device

Variable Size: 1

Variable DataType: BitEnum

Variable Enum Value Variable Enum Text
0x0001 Valve Travel Detector Failure
0x0002 Valve Travel Detector Out of Range
0x0004 A/D Conversion Module 1 Failure
0x0008 A/D Conversion Module 2 Failure
0x0010 Po 1 Pressure Sensor Failure
0x0020 Po 2 Pressure Sensor Failure
0x0040 Ps Pressure Sensor Failure
0x0080 Pn Pressure Sensor Failure

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
48 1043 read_additional_device_status

Variable Write Command List

None