Loading…

Variable Name: response_code

Variable ID: 0x0096

Variable Label: Response code

Variable Help: Command Specific Response Code- Data that is returned in the Field Device response, that indicates the relative success of the Command sent in the Host request. This information may relate to the Data of the Host request or to the command itself.

Variable Handling: R

Variable Class: Diagnostic | HART

Variable Size: 1

Variable DataType: Enum

Variable Enum Value Variable Enum Text
0x0000 Success
0x0002 Invalid selection
0x0003 Value was too high
0x0004 Value was too low
0x0005 Too few data bytes received
0x0006 Field device specific error
0x0007 In write protect mode
0x0010 Access restricted
0x0020 Busy
0x0021 Delayed response initiated
0x0022 Delayed response running
0x0023 Delayed response dead
0x0024 Delayed response conflict
0x0040 Command not implemented

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
134 408A read_prom_id
176 408B read_low_flow_cut
178 40BA read_remote_seal_height
180 408D read_meter_config
182 408F read_limit_value
184 4091 read_de_conf
188 4093 read_alarm_config
190 4095 read_status_record
194 4098 read_zero_correct_record
198 4099 read_alarm_state
200 409A read_user_define_unit
202 409C read_system_para
208 409D read_contact_output_conf
214 40A1 read_write_protect
216 40A3 read_fw_sw_ver
220 419B read_press_freq_index
222 419D read_press_freq_sensor_select
224 419F read_press_freq_diag_config
226 41A1 read_press_freq_diag_alarm_config
228 41A3 read_overload_count
230 41A5 read_overload_config
232 41A7 read_overload_alarm_config
234 41A9 read_standard_deviation
236 41AB read_standard_deviation_config
238 41AD read_standard_deviation_alarm_config
240 41AF read_production_number
242 41B0 read_device_status
244 41B1 read_device_status_records
0 00AE read_unique_identifier
1 00AF read_pv
2 00B0 read_pv_current_and_percent_range
3 00B1 read_dynamic_variables_and_pv_current
9 00DD read_device_variables_and_status
7 00DB read_loop_configuration
8 00DC read_dynamic_variable_classification
14 00B6 read_pv_sensor_info
15 00B7 read_pv_output_info
12 00B4 read_message
13 00B5 read_tag_descriptor_date
16 00B8 read_final_assembly_number
20 00DE read_long_tag
48 1043 read_additional_device_status
48 1043 read_additional_device_status
33 1054 read_device_variables
95 11DD read_device_communication_statistics

Variable Write Command List

None