Loading…
Loading…
Variable Name: DiagElectronics
Variable ID: 0x400A
Variable Label: Electronics
Variable Help:
Variable Handling: R
Variable Class: Dynamic | Correction
Variable Size: 2
Variable DataType: BitEnum
Variable Enum Value | Variable Enum Text |
---|---|
0x0100 | Temp. meas. error |
0x0200 | Dev. out of spec. |
0x0400 | EEPROM defect |
0x0800 | Writes exceeded |
0x1000 | EEPROM Data defect |
0x2000 | Parameter failure |
0x4000 | HMI not connected |
0x8000 | Device is readonly |
0x0001 | EEPROM busy |
0x0008 | Snsrbrd comm. error |
0x0010 | Snsrbrd failure |
0x0020 | Snsrbrd ADC failure |
Variable Display Format:
Variable Edit Format:
Variable Unit:
Variable Max: N/A
Variable Min: N/A
Variable Read Command List
Command Number | Command ID | Command Name |
---|---|---|
48 | 1043 | read_additional_device_status |
Variable Write Command List
None