Loading…

Variable Name: response_code

Variable ID: 0x0096

Variable Label:

Variable Help: Command Specific Response Code- Data that is returned in the Field Device response, that indicates the relative success of the Command sent in the Host request. This information may relate to the Data of the Host request or to the command itself.

Variable Handling: R/W

Variable Class: Diagnostic | HART

Variable Size: 1

Variable DataType: Enum

Variable Enum Value Variable Enum Text
0x0000 Success

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
128 400E read_secondary_output
129 4011 read_secondary_output_ranges_units
131 4015 read_temp_alarm_setpoints
133 4019 read_output_options
135 401F read_lo_func_gen_values
136 4020 read_hi_func_gen_values
141 4029 read_mfg_cell_data
142 402D read_nomenclature
143 402F read_statistics
0 00AE read_unique_identifier
1 00AF read_pv
2 00B0 read_pv_current_and_percent_range
3 00B1 read_dynamic_variables_and_pv_current
12 00B4 read_message
13 00B5 read_tag_descriptor_date
14 00B6 read_pv_sensor_info
15 00B7 read_pv_output_info
16 00B8 read_final_assembly_number
48 0FCE read_additional_transmitter_status

Variable Write Command List

None