Loading…

Variable Name: response_code

Variable ID: 0x0096

Variable Label: Response code

Variable Help: Command Specific Response Code- Data that is returned in the Field Device response, that indicates the relative success of the Command sent in the Host request. This information may relate to the Data of the Host request or to the command itself.

Variable Handling: R

Variable Class: Diagnostic | HART

Variable Size: 1

Variable DataType: Enum

Variable Enum Value Variable Enum Text
0x0000 Success
0x0002 Invalid selection
0x0003 Value was too high
0x0004 Value was too low
0x0005 Too few data bytes received
0x0006 Field device specific error
0x0007 In write protect mode
0x0010 Access restricted
0x0020 Busy
0x0021 Delayed response initiated
0x0022 Delayed response running
0x0023 Delayed response dead
0x0024 Delayed response conflict
0x0040 Command not implemented

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
144 414B read_temperature_sensor_range_values
146 4150 read_sensor_info
151 415A read_basic_device_setup
153 4170 read_simulation_parameters
154 4173 read_process_alarm_status
162 4179 read_alarm_information
170 419C read_linearization_point
170 419C read_linearization_point
170 419C read_linearization_point
170 419C read_linearization_point
170 419C read_linearization_point
170 419C read_linearization_point
170 419C read_linearization_point
170 419C read_linearization_point
170 419C read_linearization_point
170 419C read_linearization_point
170 419C read_linearization_point
170 419C read_linearization_point
170 419C read_linearization_point
170 419C read_linearization_point
170 419C read_linearization_point
170 419C read_linearization_point
170 419C read_linearization_point
170 419C read_linearization_point
170 419C read_linearization_point
170 419C read_linearization_point
170 419C read_linearization_point
173 41BC read_linearization_table_configuration
180 422C read_waveform_parameters_at_Set_Value
181 4238 read_device_variable_range_values
183 423A read_waveform_settings
193 4248 read_HMI_display_settings
195 424C read_HMI_settings
199 428E read_diagnosis_condition_details
199 428E read_diagnosis_condition_details
199 428E read_diagnosis_condition_details
199 428E read_diagnosis_condition_details
199 428E read_diagnosis_condition_details
199 428E read_diagnosis_condition_details
199 428E read_diagnosis_condition_details
199 428E read_diagnosis_condition_details
199 428E read_diagnosis_condition_details
199 428E read_diagnosis_condition_details
199 428E read_diagnosis_condition_details
199 428E read_diagnosis_condition_details
199 428E read_diagnosis_condition_details
199 428E read_diagnosis_condition_details
199 428E read_diagnosis_condition_details
199 428E read_diagnosis_condition_details
199 428E read_diagnosis_condition_details
199 428E read_diagnosis_condition_details
200 428F read_diagnosis_masking
202 4299 read_diagnosis_simulation
211 429B read_temperature_alarm_info
213 42A5 Read_Electronics_Temperature_Value
214 42A6 Read_Temperature_History_Values
221 42AE read_access_level
225 42B1 read_sensor_ID
234 42B8 read_non_media_level_alarm_settings
2816 42EB read_level_status
2817 42FE read_level_family_capability
2818 4302 read_level_family_device_variable_codes
2818 4302 read_level_family_device_variable_codes
2819 4304 read_level_family_variable_classification
2820 4314 read_level_family_device_variable_values
2821 4325 read_level_family_internal_variable_values
2822 4327 read_sensor_settings_values
2822 4327 read_sensor_settings_values
2823 432B read_level_settings_values
2823 432B read_level_settings_values
2824 4332 read_level_alarm_settings_alarm_limits
2825 4335 read_distance_settings_values
2826 4338 read_calibration_point
2826 4338 read_calibration_point
2826 4338 read_calibration_point
2826 4338 read_calibration_point
2827 4339 read_calibration_information
0 00AE read_unique_identifier
1 00AF read_pv
2 00B0 read_pv_current_and_percent_range
3 00B1 read_dynamic_variables_and_pv_current
9 00DD read_device_variables_and_status
7 00DB read_loop_configuration
8 00DC read_dynamic_variable_classification
14 00B6 read_pv_sensor_info
15 00B7 read_pv_output_info
12 00B4 read_message
13 00B5 read_tag_descriptor_date
16 00B8 read_final_assembly_number
20 00DE read_long_tag
48 1043 read_additional_device_status
48 1043 read_additional_device_status
33 1054 read_device_variables
50 1052 read_device_variable_assignments
54 1057 read_device_variable_information
76 1045 read_lock_device_state

Variable Write Command List

None