Variable Name: pressure_units

Variable ID: 0x138D

Variable Label: Ед.изм. давления

Variable Help: Field Device Variable Unit- unit in which digital value, minimum span, upper range value, lower range value, lower sensor limit, upper sensor limit, lower sensor trim point and upper sensor trim point are displayed. Pressure- Measured process pressure in relation to a reference pressure.

Variable Handling: R/W

Variable Class: Correction

Variable Size: 1

Variable DataType: Enum

Variable Enum Value Variable Enum Text
0x0001 inH2O
0x0002 inHg
0x0003 ftH2O
0x0004 mmH2O
0x0005 mmHg
0x0006 psi
0x0007 bar
0x0008 mbar
0x0009 g/Sqcm
0x000A kg/Sqcm
0x000B Pa
0x000C kPa
0x000D torr
0x000E atm

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
128 4019 read_static_data_material
225 401D read_all_measured_values
1 00AF read_pv
3 00B1 read_dynamic_variables_and_pv_current
14 00B6 read_pv_sensor_info
15 00B7 read_pv_output_info

Variable Write Command List

Command Number Command ID Command Name
44 0FB1 write_pv_units