0x178F016E |
expd_dev_rev_help |
Expected Device Revision is a parameter that the configuration tool expects to describe the VFD referred to by VFD_REF. The actual values can be determined by accessing the resource block of the VFD referred to via VFD_REF. If there is a mismatch, it shall also be reflected in the ELEM_MISMAT_xx as described in FF-061. |
0x178F016F |
expd_dd_rev_label |
Expected DD Revision |
0x178F0170 |
expd_dd_rev_help |
Expected DD Revision is a parameter that the configuration tool expects to describe the VFD referred to by VFD_REF. The actual values can be determined by accessing the resource block of the VFD referred to via VFD_REF. If there is a mismatch, it shall also be reflected in the ELEM_MISMAT_xx as described in FF-061. |
0x178F0171 |
vfd_ref_label |
VFD Reference |
0x178F0172 |
vfd_ref_help |
The current FBAP VFD Ref, as defined in FF589, chapter 6.2.4 VFD list. |
0x178F0173 |
process_value_range_a_8_label |
Process Value Range A 8 |
0x178F0174 |
process_value_range_a_9_label |
Process Value Range A 9 |
0x178F0175 |
process_value_range_a_10_label |
Process Value Range A 10 |
0x178F0176 |
process_value_range_a_11_label |
Process Value Range A 11 |
0x178F0177 |
process_value_range_a_12_label |
Process Value Range A 12 |
0x178F0178 |
process_value_range_a_13_label |
Process Value Range A 13 |
0x178F0179 |
process_value_range_a_14_label |
Process Value Range A 14 |
0x178F017A |
process_value_range_a_15_label |
Process Value Range A 15 |
0x178F017B |
process_value_range_a_16_label |
Process Value Range A 16 |
0x178F017C |
io_threshold_a_9_label |
IO Threshold A 9 |
0x178F017D |
io_threshold_a_10_label |
IO Threshold A 10 |
0x178F017E |
io_threshold_a_11_label |
IO Threshold A 11 |
0x178F017F |
io_threshold_a_12_label |
IO Threshold A 12 |
0x178F0180 |
io_threshold_a_13_label |
IO Threshold A 13 |
0x178F0181 |
io_threshold_a_14_label |
IO Threshold A 14 |
0x178F0182 |
io_threshold_a_15_label |
IO Threshold A 15 |
0x178F0183 |
io_threshold_a_16_label |
IO Threshold A 16 |
0x178F0184 |
__outm_b64_label |
Output Binary 64 |
0x178F0185 |
__outm_b64_help |
The64 primary binary values calculated as a result of executing the function block. |
0x178F0186 |
force_enb_b64_label |
Force Enable Binary 64 |
0x178F0187 |
force_enb_b64_help |
Controls the updating of each of the 64 Boolean points when the block is in AUTO mode. A value of 1 will stop the updating of the corresponding input/output point. |
0x178F0188 |
force_val_b64_label |
Force Value Binary 64 |
0x178F0189 |
force_val_b64_help |
Supplies the value(s) for each of the 64 Boolean points when corresponding bits in FORCE_ENB_B64 are set to 1 in AUTO mode. |
0x178F018A |
dup_var_name_def_9_label |
Duplicate Var Name Definition 9 |
0x178F018B |
dup_var_name_def_9_help |
A 16 bit bit string for indications of multiply defined tags for each field point defined in VAR_NAMES9. LSB signals an error of VAR_NAMES9.NAME1. |
0x178F018C |
enumerated |
enumerated |
0x178F018D |
hart_address_label |
HART Address |
0x178F018E |
hart_address_help |
Address assigned to the device by the HART network manager. '0' if none. |
0x178F018F |
hart_device_type_label |
HART Device Type |
0x178F0190 |
hart_device_type_help |
An enumeration indicating the manufacturer?s type of the device, i.e., the product name as specified in HCF_SPEC-183 Table 1. |
0x178F0191 |
hart_manufacturer_id_label |
HART Manufacturer ID |
0x178F0192 |
hart_manufacturer_id_help |
An enumeration indicating the manufacturer?s identification code as specified in HCF_SPEC-183 Table 8. |
0x178F0193 |
hart_distributor_id_label |
HART Distributor ID |
0x178F0194 |
hart_distributor_id_help |
An integer indicating the private label manufacturer that distributed the device as specified in HCF_SPEC-183 Table 8. The value for this parameter needs to be entered by the user using information in the device manual or reading data from HART_ACTL_DEV_INFO. |
0x178F0195 |
hart_device_profile_label |
HART Device Profile |
0x178F0196 |
hart_device_profile_help |
An integer specifying the class to which the device belongs as specified in HCF_SPEC-183 Table 57. The value for this parameter needs to be entered by the user using information in the device manual or reading data from HART_ACTL_DEV_INFO |
0x178F0197 |
hart_device_id_label |
HART Device ID |
0x178F0198 |
hart_device_id_help |
Serial number for the device. The manufacturer is required to assign a unique value for every device within a given Manufacturer ID and Device Type. |
0x178F0199 |
response_code_label |
Response Code |
0x178F019A |
response_code_help |
Contains the value of the Foreign Protocol communication status, in the Transducer Block for HART Device (TB-HART) the communication status is given by HART_COM_STAT parameter. |
0x178F019B |
response_message_label |
Response Message |
0x178F019C |
response_message_help |
Contains the value of the Foreign Protocol response, in the Transducer Block for HART Device (TB-HART) the repsonse is given by HART_RESP parameter. |
0x178F019D |
var_dir9_entry_label |
Var Dir 9 Array Entry |
0x178F019E |
var_dir9_Entry_help |
Var Dir 9 Array Entry |
0x178F019F |
seconds |
seconds |